Climate sensor
Temperature and humidity of a room.
A device is a board on the radio. Each thing it measures is a sensor of its own in Mizelum, with its own name, gauge and graph.
Temperature and humidity of a room.
The weather outside: air, wind and rain.
What is in the air indoors, and how loud it is.
What a circuit draws, and whether it is switched on.
How full a tank is, and whether it is leaking.
Motion, light, a door or window, and smoke.
How moist and how warm the soil is.
Light, UV index and distance.
The weight on it, and the temperature.
Relays you switch from the dashboard or the terminal.
Heating, cooling and the fan, switched from Mizelum.
The first sensor: a counter, to prove the radio link.
A report is a list of readings, each a tag byte and its value. The top two bits of the tag say how long the value is, so a receiver can skip a reading it does not know.
| Kind | Tag | Sent as | Carried by |
|---|---|---|---|
| Temperature | 0x42 | i16, 0.01 °C | Climate sensor, Weather station, Air monitor, Tank monitor, Soil probe, Scale, HVAC unit |
| Relative humidity | 0x43 | u16, 0.01 % | Climate sensor, Weather station, Air monitor, HVAC unit |
| Air pressure | 0x48 | u16, 0.1 hPa | Weather station |
| CO2 | 0x47 | u16, ppm | Air monitor |
| Fine dust (PM1.0) | 0x5E | u16, 0.1 µg/m³ | |
| Fine dust (PM2.5) | 0x54 | u16, 0.1 µg/m³ | Air monitor |
| Dust (PM10) | 0x5F | u16, 0.1 µg/m³ | |
| Particulate matter | 0x5B | u16, 0.1 ppm | Air monitor |
| Air quality (VOC index) | 0x58 | u16 | Air monitor |
| Sound level | 0x55 | u16, 0.1 dB | Air monitor |
| Light | 0x86 | u32, lux | Room sensor, Light sensor |
| UV index | 0x56 | u16, 0.01 | Light sensor |
| Rain fallen | 0x50 | u16, 0.1 mm | Weather station |
| Wind speed | 0x51 | u16, 0.01 m/s | Weather station |
| Wind direction | 0x52 | u16, degrees | Weather station |
| Soil moisture | 0x53 | u16, 0.01 % | Soil probe |
| Water level | 0x4F | u16, mm | Tank monitor |
| Volume | 0x9D | u32, 0.1 litre | Tank monitor |
| Water leak | 0x19 | u8, 0 dry, 1 wet | Tank monitor |
| Weight | 0x9C | u32, 0.01 kg | Scale |
| Distance | 0x57 | u16, mm | Light sensor |
| Power | 0x89 | i32, 0.1 W; negative when exporting | Energy meter, HVAC unit |
| Current | 0x4A | u16, 0.01 A | Energy meter, HVAC unit |
| Voltage | 0x4B | u16, 0.1 V | Energy meter |
| Energy used | 0x8C | u32, Wh | Energy meter |
| Switch | 0x0D | u8, 0 off, 1 on | Energy meter, Relay board, HVAC unit |
| Motion | 0x0E | u8, 0 clear, 1 motion | Room sensor |
| Contact | 0x05 | u8, 0 open, 1 closed | Room sensor |
| Smoke | 0x1A | u8, 0 clear, 1 smoke | Room sensor |
| Counter | 0x84 | u32 | Test sensor |
The supply voltage (0x41) is sent the same way but is not a sensor: it is the condition of the device, shown with each of its sensors.