Mizelum
← Sensors

Energy meter

Voltage, current and power now, and the energy used so far. Power is signed, so a circuit that feeds back (solar) reads negative.

Readings

5 sensors
SwitchON51330005-0D
Voltage230.1V51330005-4B
Current1.49A51330005-4A
Power342.5W51330005-89
Energy used18420Wh51330005-8C

Example readings

Device

Status
Simulated
Device type
0x0005
Link
2.4 GHz radio (nRF24L01+)
Report
21 of 25 bytes, with the supply voltage

A device type named in the protocol. The simulated hub has one, so the software can already show it; there is no hardware or firmware yet.

On the radio

What it sends

Every report carries the readings below, in this order, after the device's supply voltage.

Report

type 2 · 21 bytes of readings
SensorTagSent asSensor id
Switch0x0Du8, 0 off, 1 on51330005-0D
Voltage0x4Bu16, 0.1 V51330005-4B
Current0x4Au16, 0.01 A51330005-4A
Power0x89i32, 0.1 W; negative when exporting51330005-89
Energy used0x8Cu32, Wh51330005-8C

Next: Tank monitor →