The fullest device in the protocol: seven readings, which with the supply voltage come to 24 of the 25 bytes a radio frame has for readings.

Readings

7 sensors
CO2612ppm51330004-47
Fine dust (PM2.5)8.4µg/m³51330004-54
Particulate matter0.6ppm51330004-5B
Air quality (VOC index)9651330004-58
Sound level42.3dB51330004-55
Temperature21.6°C51330004-42
Relative humidity48.2%51330004-43

Example readings

Device

Status
Simulated
Device type
0x0004
Link
2.4 GHz radio (nRF24L01+)
Report
24 of 25 bytes, with the supply voltage

A device type named in the protocol. The simulated hub has one, so the software can already show it; there is no hardware or firmware yet.

On the radio

What it sends

Every report carries the readings below, in this order, after the device's supply voltage.

Report

type 2 · 24 bytes of readings
SensorTagSent asSensor id
CO20x47u16, ppm51330004-47
Fine dust (PM2.5)0x54u16, 0.1 µg/m³51330004-54
Particulate matter0x5Bu16, 0.1 ppm51330004-5B
Air quality (VOC index)0x58u1651330004-58
Sound level0x55u16, 0.1 dB51330004-55
Temperature0x42i16, 0.01 °C51330004-42
Relative humidity0x43u16, 0.01 %51330004-43