Mizelum
← Sensors

Room sensor

Three of its four readings are not numbers but states: motion or clear, open or closed, smoke or clear. Mizelum writes those out in words.

Readings

4 sensors
MotionCLEAR51330007-0E
Light640lx51330007-86
ContactCLOSED51330007-05
SmokeCLEAR51330007-1A

Example readings

Device

Status
Simulated
Device type
0x0007
Link
2.4 GHz radio (nRF24L01+)
Report
14 of 25 bytes, with the supply voltage

A device type named in the protocol. The simulated hub has one, so the software can already show it; there is no hardware or firmware yet.

On the radio

What it sends

Every report carries the readings below, in this order, after the device's supply voltage.

Report

type 2 · 14 bytes of readings
SensorTagSent asSensor id
Motion0x0Eu8, 0 clear, 1 motion51330007-0E
Light0x86u32, lux51330007-86
Contact0x05u8, 0 open, 1 closed51330007-05
Smoke0x1Au8, 0 clear, 1 smoke51330007-1A

Next: Soil probe →